Volt Meter Gauge: Description and Operation

DELCOTRON CHARGING SYSTEM

    The CS generator uses a new type of regulator which has a built in fault detection. The CS generator does not have a diode trio or test hole. This
generator uses only two connections, battery positive and an ``L'' terminal to the charge indicator bulb. Use of ``P,'' ``F'' and ``S'' terminals is optional.
The ``P'' terminal is connected to the stator and may be connected to a tachometer or other device. The ``F'' terminal is connected internally to field
positive and is used in service diagnostics. The ``S'' terminal may be connected externally to a voltage source, such as battery voltage.