Oxygen Sensor: Description and Operation

Oxygen Sensor

The Oxygen (02) Sensor is mounted in the exhaust system where it can monitor the oxygen content of the exhaust gas stream. The oxygen content in the
exhaust reacts with the sensor to produce a voltage output. This voltage ranges from approximately 0.1 volt (high 02 - lean mixture) to .9 Volts (low 02 -
rich mixture). This voltage can be measured with a digital voltmeter having at least 10 Meg ohms input impedance, or displayed on a scan tool. Use of
standard shop type voltmeters will result in very inaccurate readings. By monitoring the voltage output of the 02 sensor, the ECM has been calibrated to
select a commanded fuel mixture at the M/C Solenoid (lean mixture - low 02 voltage = rich command, rich mixture - high 02 voltage = lean command).