Adjusting Installation Angle Of TPS

5.

With a DVOM (digital volt ohm meter) connected between terminals C and D of the TPS connector, rotate the TPS fully clockwise. Then
gradually rotate the TPS counterclockwise until the DVOM reads continuity.