2. Disconnect the electrical connector (4) from the right air temperature actuator (3).
3. Remove the screws from the right air temperature actuator (3).
4. Remove the right air temperature actuator (3) from the HVAC module assembly (2).
INSTALLATION PROCEDURE
1. Install the right air temperature actuator (3) from the HVAC module assembly (2).
2. Install the screws to the right air temperature actuator (3).
Notice: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the screws to 2 N.m (18 lb in).
3. Connect the electrical connector to the right air temperature actuator.
4. Install the I/P carrier.
5. Reprogram the air temperature actuator. See: Testing and Inspection/Programming and Relearning
Mode Actuator Replacement (W/ D07)
REMOVAL PROCEDURE