10. Install the air cleaner outlet duct.
11. Align the arrow at the throttle body end of the duct with the throttle body attaching stud.
Notice:
Refer to Fastener Notice in Service Precautions.
See: Engine, Cooling and Exhaust/Service Precautions/Vehicle Damage Warnings/Fastener Notice
12. Tighten the air cleaner outlet duct clamps at the following locations:
-
Throttle body
-
MAF/IAT sensor
Tighten the clamps to 7 Nm (62 inch lbs.).
13. Fill the cooling system.