C 1500 Yukon 2WD V8-5.3L VIN Z Flex Fuel (2003)
Generator: Service and Repair
Generator Replacement
REMOVAL PROCEDURE
1. Disconnect the negative battery cable.
2. Remove the accessory drive belt.
3. If necessary, remove the engine sight shield.
4. Disconnect the generator electrical connector (3).
5. Remove the generator cable from the generator, perform the following:
5.1.
Slide the boot down revealing the terminal stud.
5.2.
Remove the generator cable nut from the terminal stud.
5.3.
Remove the generator cable.