gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Blower Motor Resistor > < Diagram Information and Instructions|Page 5345
Page 2
background image

Fig. 6 Rear duct assembly. R & V Series with overhead system

OVERHEAD UNIT

1.

Disconnect battery ground cable.

2.

Remove rear duct drain tube, duct to header bracket and roof panel screws, then rear duct assembly, Fig. 6.

Fig. 7 Rear blower motor & evaporator assembly. R & V Series with overhead system

3.

Disconnect blower motor harness lead and ground wire, Fig. 7.

4.

While supporting lower case to prevent damage to motor or case assemblies, remove case mounting screws, then lower case from vehicle roof.

5.

Remove motor retaining strap, then lift motor and cage assembly from case. Remove cages by removing shaft retaining nuts.

6.

Reverse procedure to install. When installing cages on motor shaft, tension springs must be installed on motor shafts. Cages should be mounted so
leading edges of blades face lower evaporator case (thin edge first). After installing blower assembly in case, check to ensure there is no
interference with rotating cages. 