C 2500 Yukon XL 2WD V8-8.1L VIN G (2002)
1. Remove the outer jacket (1). Use care not to cut into the drain wire of the MYLAR tape.
2. Unwrap the tape. Do not remove the tape. Use the tape in order to rewrap the twisted conductors after the splice is made.
3. Prepare the splice. Untwist the conductors and follow the splicing instructions for copper wire. Staggering the splices by 65 mm is recommended.
IMPORTANT: Apply the MYLAR tape with the aluminum side inward. This ensures good electrical contact with the drain wire.
4. Re-assemble the cable.