7. Squeeze the poppet nozzle locking tabs together while lifting the nozzle out of the casting socket.
8. Remove the fuel meter body from the bracket by releasing the lock tabs on the bracket.
INSTALLATION PROCEDURE
NOTE: Refer to Fastener Notice in Cautions and Notices.
1. Install the fuel meter body retaining bracket in the intake manifold.
Tighten
Tighten the attaching bolts to 10.0 N.m (88 lb in).