Canyon 2WD L4-2.9L (2008)
Hose/Line HVAC: Service and Repair
Suction Hose Replacement
Suction Hose Replacement (LLV - 2.9L, LLR - 3.7L)
Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging (Non HP2) (See: Heating and Air Conditioning/Service and
Repair/Refrigerant Recovery and Recharging (Non HP2)) .
2. Remove the generator. Refer to Generator Replacement (See: Starting and Charging/Charging System/Alternator/Service and Repair) .
3. Remove the suction hose mounting bolt (1) from the A/C compressor (7).