4. Connect the generator lead (5) to the generator and install the generator output BAT terminal nut (6).

Tighten
Tighten the generator output BAT terminal nut to 20 N.m (15 lb ft).

5. Press the protective boot (4) on to the generator output BAT terminal (2).
6. Connect the wiring harness connector (1) to the generator.
7. Raise and support the vehicle only high enough to access the A/C compressor through the wheelhouse. Refer to Vehicle Lifting.

8. Position the A/C compressor (1) to the engine.
9. Install the A/C compressor mounting bolts (2, 3).

Tighten
Tighten the A/C compressor mounting bolts to 50 N.m (37 lb ft).

10. Attach the A/C compressor electrical connector to the bracket.
11. Install the left wheelhouse liner.
12. Install the left front wheel.
13. Lower the vehicle.
14. Install the drive belt.
15. Connect the battery negative cable.