gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

HVAC - Automatic|Page 16276 > < HVAC - Automatic|Page 16274
Page 5
background image

1. Install the recirculation actuator.

Notice:  Refer to Fastener Notice.

2. Install the screws to the recirculation actuator.

Tighten the screws to 1.9 N.m (17 lb in).

3. Install the air inlet assembly.
4. Install the air inlet assembly screws.

Tighten the screws to 1.9 N.m (17 lb in).

5. Connect the electrical connector to the recirculation actuator.
6. Install the HVAC module assembly.
7. Recalibrate the recirculation actuator. Refer to Actuators Recalibration (Auxiliary HVAC) Actuators Recalibration (Primary)

Mode Actuator Replacement - Console

Mode Actuator Replacement - Console

Removal Procedure

1. Remove the floor console.
2. Rotate the console.
3. Remove the screw from the air outlet duct.
4. Remove the air outlet duct from the floor console.

5. Remove the rear mode actuator retaining screws.
6. Disconnect the electrical connector.

7. Remove the rear mode actuator.

Installation Procedure

HVAC - Automatic|Page 16276 > < HVAC - Automatic|Page 16274