K 2500 Truck 4WD V8-8.1L VIN G (2001)
3. Prepare the splice. Untwist the conductors and follow the splicing instructions for copper wire. Staggering the splices by 65 mm is recommended.
IMPORTANT: Apply the MYLAR tape with the aluminum side inward. This ensures good electrical contact with the drain wire.
4. Re-assemble the cable.
-
Rewrap the conductors with the MYLAR tape.
-
Use caution not to wrap the drain wire in the tape (1).
-
Follow the splicing instructions for copper wire and splice the drain wire.
-
Wrap the drain wire around the conductors and tape with MYLAR tape.