K 3500 Truck 4WD V8-393 6.5L DSL Turbo VIN S (1995)
![background image](/gmc/k_3500_truck_4wd/v8-393_6.5l_dsl_turbo_vin_s/Page-1102001.png)
Shift Solenoid: Description and Operation
1-2 Shift Solenoid
1-2 Shift Solenoid And 2-3 Shift Solenoid
Shift Solenoid Chart
DESCRIPTION
This electrical device is used to control fluid flow acting on the 1-2 and 3-4 shift valves. The solenoid is a normally open exhaust valve that is used
with the 2-3 shift solenoid to allow four different shifting combinations. The solenoid is attached to the control valve body within the transmission.