1. Install the accumulator into the accumulator clamp.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the accumulator clamp bolt.

Tighten
Tighten the accumulator clamp bolt to 10 N.m (88 lb in).

3. Install the A/C low pressure switch.

4. Install new O-ring seals.
5. Connect the compressor hose assembly to the accumulator (2).

Tighten
Tighten the compressor suction hose to accumulator retaining nut to 48 N.m (35 lb in).

6. Install the accumulator to evaporator retaining nut.

Tighten
Tighten the accumulator to evaporator retaining nut to 28 N.m (21 lb ft).

7. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
8. Leak test the fittings components using the J 39400-A.