Metri-pack Connector

Install or Connect

1. Terminal (16) on the wire.

^

Crimp and solder the terminal.

2. Terminal (16) into the connector cavity by pulling the wire on the seal side of the connector until the locking tang (18) is fully seated.
3. Seal (1) by pressing the seal into the connector body(17) until it is fully seated.
4. Connector sections until the primary lock (2) engages.