3. Install the compressor hose assembly (2) to the accumulator (1).

Tighten
Tighten the compressor hose assembly (2) to the accumulator (1) to 48 N.m (35 lb ft).

4. Install the coolant recovery or surge tank.
5. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
6. Leak test the fittings of the component using the J 39400-A.