Housing Assembly HVAC: Description and Operation
Air Speed - Front and Rear Auxiliary HVAC

General Information

The auxiliary blower motor recycles air from the vehicle's interior. The vehicle operator determines the auxiliary blower motor's speed by placing the
front auxiliary HVAC control assembly in one of the following positions: Low, Med, or High. Rear seat passengers on passenger van models can adjust
the auxiliary blower motor speed by using the rear auxiliary HVAC control assembly. The auxiliary blower motor will only operate when the ignition is
in the RUN position, and the front auxiliary HVAC control assembly is in any position other than OFF. The rear auxiliary HVAC control assembly will
operate in any position other than the OFF position, as long as the front auxiliary HVAC control assembly is in the REAR CNTL position.

Power is provided to the auxiliary blower motor from the underhood fuse block on the battery positive voltage circuit through the convenience center.
The IP fuse block provides power to the control side of the auxiliary blower motor relays through the ignition 1 voltage circuit and convenience center.

Off Mode

When the OFF blower setting is selected on the front auxiliary HVAC control assembly, the switch creates an open circuit within the front auxiliary
HVAC control assembly. This prevents any output being provided by either the front or rear auxiliary HVAC control assembly. If the OFF blower
setting is selected on the rear auxiliary HVAC control assembly, the switch will create an open within the rear auxiliary HVAC control assembly. This
prevents any output being provided to the auxiliary blower motor, as long as the front auxiliary HVAC control assembly is in the OFF position. The front
auxiliary HVAC control assembly controls the rear auxiliary HVAC control assembly on the auxiliary blower motor switch control circuit.

Auxiliary Low Blower Speed

When the Low blower speed is selected at the front auxiliary HVAC control assembly, the front auxiliary HVAC control assembly applies a ground to
the auxiliary low speed blower motor relay through the auxiliary blower motor low speed control circuit. When the relay closes its switch, voltage is
provided by the battery positive voltage circuit. Voltage is divided between 2 series resistors in the auxiliary blower motor resistor assembly and the
auxiliary blower motor to achieve the desired blower speed. The auxiliary blower motor is included in the series circuit by the auxiliary blower motor
supply voltage and ground circuits. The auxiliary blower motor switch and auxiliary blower motor are grounded by the ground circuit.

When the Low blower speed is selected at the rear auxiliary HVAC control assembly, the rear auxiliary HVAC control assembly applies a ground to the
auxiliary low speed blower motor relay through the auxiliary blower motor low speed control circuit, the auxiliary blower motor switch control circuit,
the auxiliary HVAC control processor, then through the REAR CNTL switch position on the front auxiliary HVAC control assembly. When the auxiliary
low speed blower motor relay closes its switch, voltage is provided by the battery positive voltage circuit. Voltage is divided between 2 series resistors in
the auxiliary blower motor resistor assembly and the auxiliary blower motor to achieve the desired blower speed. The auxiliary blower motor is included
in the series circuit by the auxiliary blower motor supply voltage and ground circuits. The auxiliary blower motor switch and auxiliary blower motor are
grounded by the ground circuit.

Auxiliary Medium Blower Speed

When the Medium blower speed is selected at the front auxiliary HVAC control assembly, the front auxiliary HVAC control assembly applies a ground
to the auxiliary medium speed blower motor relay through the auxiliary blower motor medium speed control circuit. When the relay closes its switch,
voltage is provided by the battery positive voltage circuit. Voltage is divided between 1 series resistor in the auxiliary blower motor resistor assembly
and the auxiliary blower motor to achieve the desired blower speed. The auxiliary blower motor is included in the series circuit by the auxiliary blower
motor supply voltage and ground circuits. The auxiliary blower motor switch and auxiliary blower motor are grounded by the ground circuit.

When the Medium blower speed is selected at the rear auxiliary HVAC control assembly, the rear auxiliary HVAC control assembly applies a ground to
the auxiliary medium speed blower motor relay through the auxiliary blower motor medium speed control circuit, the auxiliary blower motor switch
control circuit, the auxiliary HVAC control processor, then through the REAR CNTL switch position on the front auxiliary HVAC control assembly.
When the auxiliary medium speed blower motor relay closes its switch, voltage is provided by the battery positive voltage circuit. Voltage is divided
between 1 series resistor in the auxiliary blower motor resistor assembly and the auxiliary blower motor to achieve the desired blower speed. The
auxiliary blower motor is included in the series circuit by the auxiliary blower motor supply voltage and ground circuits. The auxiliary blower motor
switch and auxiliary blower motor are grounded by the ground circuit.

Auxiliary High Blower Speed

When the High blower speed is selected at the front auxiliary HVAC control assembly, the front auxiliary HVAC control assembly applies a ground to
the auxiliary high speed blower motor relay through the auxiliary blower motor high speed control circuit. When the relay closes its switch, voltage is
provided by the battery positive voltage circuit. Voltage is sent directly to the auxiliary blower motor by the auxiliary blower motor supply voltage
circuit. The auxiliary blower motor switch and auxiliary blower motor are grounded by the ground circuit.

When the High blower speed is selected at the rear auxiliary HVAC control assembly, the rear auxiliary HVAC control assembly applies a ground to the
auxiliary high speed blower motor relay through the auxiliary blower motor high speed control circuit, the auxiliary blower motor switch control circuit,
the auxiliary HVAC control processor, then through the REAR CNTL switch position on the front auxiliary HVAC control assembly. When the auxiliary
high speed blower motor relay closes its switch, voltage is provided by the battery positive voltage circuit. Voltage is sent directly to the auxiliary blower
motor by the auxiliary blower motor supply voltage circuit. The auxiliary blower motor switch and auxiliary blower motor are grounded by the ground
circuit.

General Information|Page 6933 > < General Information|Page 6931