Sierra Classic 1500 2WD V8-4.8L (2007)
MOLEX CONNECTORS
TOOLS REQUIRED
J-38125 Terminal Repair Kit
TERMINAL REMOVAL PROCEDURE
1. Locate the connector position assurance (CPA) on the top of the wire dress cover. Slide the CPA forward.
2. Slide the lever lock forward while pressing down on the lever lock release tab.
3. The lever should be in the full forward position.