gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

M/T - Updated Gaskets|Page 3936 > < M/T - Updated Gaskets|Page 3934
Page 3
background image

FIGURE 1 - NEW GASKETS

For all models, install the new gaskets and put pipe sealant with teflon (TM) or equivalent on all the bolts. Put pipe sealant with teflon (TM) or
equivalent on the drain and fill plugs (76), then torque all bolts and plugs to the specifications listed in Figure 1. The countershaft front bearing cap bolt
(73) torque specification has been increased to 4 N-m (3 ft.lbs.) to prevent leakage.
SERVICE PARTS INFORMATION:

P/N 8672945 New Service Parts Gasket and Seal Package Contents:

Quantity

Part Description

1

Gasket, Rear Bearing Retainer (2WD and 4WD)

1

Gasket, Main Drive Gear Bearing Retainer

1

Gasket, Countershaft Front Bearing Cap

2

Gasket, Power Take Off Cover

1

Gasket, Cover

1

Seal, Main Drive Gear Bearing oil

1

Seal, U-Joint Front Flange Oil

Listed below are sealants referred to in this bulletin:

Quantity

Part No.

Part Description

1

1052080

Pipe Sealant with Teflon (TM) (50 ml - 

1.69 oz)

1

1052917

RTV Silicone GMS Type B (89 ml - 3 oz)

SERVICE MANUAL REFERENCE:

Refer to the unit repair section of the appropriate service manual for the procedures.

Please record this information in any 1988 or earlier model year service manual. 1989 and future service manuals will include these revisions.

M/T - Updated Gaskets|Page 3936 > < M/T - Updated Gaskets|Page 3934