Syclone V6-262 4.3L Turbo (1991)
Blower Motor: Description and Operation
CIRCUIT OPERATION
The Blower Motor Fan delivers air to the interior of the vehicle. Its speed is controlled by the Blower Switch and the Blower Resistors. When the
Ignition Switch is in RUN, battery voltage is applied 10 the Blower Switch through the HTR-A/C Fuse. With the Blower Switch in LO, voltage is
applied across both Blower Resistors and the Blower Motor. The Blower Motor runs at its slowest speed. With the Blower Switch in MED, one of the
Blower Resistors is bypassed and the Blower Motor runs faster. When the Blower Switch is set to HI, battery voltage is applied directly to the Blower
Motor and the Blower Motor runs at its fastest speed.