gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Control Assembly, HVAC > < Condenser HVAC|Description and Operation|Page 6287
Page 1
background image

Condenser HVAC: Service and Repair

Condenser Replacement

REMOVE OR DISCONNECT 

1. Refrigerant from the system.

2. Upper fan shroud.

3. Radiator.

4. Shields at either side of the radiator Support.

5. Condenser retainers (121) and insulators (120).

6. Condenser lines (110 and 111).

7. Condenser (21).

INSTALL OR CONNECT 

1. Condenser (2).

2. Condenser retainers (121) and insulators (120)

-

Tighten mounting bolts (122) to 6 Nm (62 in. lbs.).

3. Condenser lines (110 and 111) to the condenser (2).

-

Tighten nuts (110 and 111) to 24 Nm (18 ft. lbs.).

4. Radiator.

5. Upper fan shroud.

6. Refrigerant to the system.

-

Evacuate, charge and leak test.

Control Assembly, HVAC > < Condenser HVAC|Description and Operation|Page 6287