Yukon/Denali XL 1500 4WD V8-6.0L VIN U (2004)
1. If installing the old sensor, coat the threads with sealant GM P/N 12346004 (Canadian P/N 10953480) or equivalent.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the ECT sensor.
Tighten the sensor to 20 N.m (15 lb ft).
3. Connect the ECT sensor electrical connector (5).
4. Refill the cooling. Refer to Draining and Filling Cooling System in Cooling System.