Yukon XL 2500 2WD V8-8.1L VIN G (2004)
REMOVAL PROCEDURE
1. Remove the air distribution duct.
2. Disconnect the electrical connection from the recirculation actuator (1).
3. Remove the recirculation actuator retaining screws.
4. Remove the recirculation actuator
.
INSTALLATION PROCEDURE
1. Install the recirculation actuator.
2. Install the recirculation actuator retaining screws.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the screws to 1.6 N.m (14 lb in).