Yukon XL 2500 4WD V8-6.0L VIN N (2006)
Cut the wires back far enough from the connector to eliminate any melted insulation on the wire.
Tip
Use the old connector as a map for splicing the wires for the new connector. Be sure to use the correct crimping tool from the terminal repair kit J 38125.
Use only Duraseal splice sleeves. Other splice sleeves may not protect the splice from moisture or provide a good electrical connection.
Install the new connector. Use the yellow splice sleeves provided with the connector.
Install new blower motor resistor.
Reinstall the fuse or connector block. Test the blower motor to make sure all speeds are functional.
Reinstall the hush panel/close-out panel.