honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Fresh Air/Recirculation Actuator|Page 3153 > < Button Type|Page 3150
Page 1
background image

Air Door Actuator / Motor: Testing and Inspection
Fresh Air/Recirculation Actuator

1. Connect a battery positive lead to Y/Bl terminal of the recirculation control motor, and negative lead to the G/Blue terminal.

-

The motor should run.

2. Connect the ohmmeter probes to the G/Y and G/R terminals.

-

The ohm meter should continue to cycle back and forth but hesitate slightly longer when indicating continuity.

3. Then connect the ohmmeter to terminals G/Y and G/W.

-

The ohmmeter should continue to cycle back and forth but hesitate slightly longer when indicating continuity.