Accord L4-1955cc 2.0L SOHC 2-bbl (1986)
Air Door Actuator / Motor: Testing and Inspection
Fresh Air/Recirculation Actuator
1. Connect a battery positive lead to Y/Bl terminal of the recirculation control motor, and negative lead to the G/Blue terminal.
-
The motor should run.
2. Connect the ohmmeter probes to the G/Y and G/R terminals.
-
The ohm meter should continue to cycle back and forth but hesitate slightly longer when indicating continuity.
3. Then connect the ohmmeter to terminals G/Y and G/W.
-
The ohmmeter should continue to cycle back and forth but hesitate slightly longer when indicating continuity.