honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Shift Arm/Selector Arm|Page 2546 > < Shift Shaft Clearance|Page 2541
Page 1
background image

Shifter M/T: Service and Repair
Shift Arm/Selector Arm

Shift Guide Clearance

1. Check shift arm-to-shift guide clearance 

Standard (New): 0.1-0.3 mm (0.004-0.012 in.) 
Service Limit: 0.6 mm (0.024 in.)

2. If not within service limit, measure width of slot in shift guide.

Standard (New): 7.9-8.0 mm (0.311-0.315 in.)

3. If slot is wider than standard, replace shift guide.

Interlock Clearance

1. Check selector arm-to-interlock clearance. 

Standard (New): 0.05-0.25 mm (0.002-0.01 in.)
Service Limit: 0.7 mm (0.03 in.)

2. If not within service limit, measure gap between selector arm fingers.

Standard (New): 10.05-10.15 mm (0.396-0.4 in.)

3. If gap is wider than standard, replace arm.

Shift Arm/Selector Arm|Page 2546 > < Shift Shaft Clearance|Page 2541