Engine Mount Control Actuator: Testing and Inspection

Vacuum Diaphragm Actuator And Mount Testing

NOTE: Before testing, clean and oil vacuum diaphragm actuator rod, engine mount rotor, and lever linkage.

1.

Disconnect hose (to vacuum diaphragm actuator) at solenoid valve and connect vacuum pump/gauge.

2.

Apply vacuum above 230 mmHg and check that rotor valve stroke is a full 80 degrees.

3.

If not as specified, and no other problem is detected, replace engine mount assembly.