honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Air Mix Control Motor Test|Page 6148 > < Air Mix Control Motor Test|Page 6146
Page 1
background image

Air Door Actuator / Motor: Testing and Inspection
Recirculation Control Motor Circuit Troubleshooting

Climate Control

Recirculation Control Motor Circuit Troubleshooting

1. Check the No.30 (7.5 A) fuse in the Under-dash fuse/relay box.

Is the fuse OK?

YES - Go to step 2.

NO - Replace the fuse, and recheck.

2. Disconnect the recirculation control motor 7P (4-door) or 5P (2-door) connector.
3. Turn the ignition switch ON (II).

4. Measure the voltage between the No.1 terminal of the recirculation control motor 7P (4-door) or No.5 terminal of the 5P (2-door) connector and

body ground.

Is there battery voltage?

YES - Go to step 5.

NO - Repair open in the wire between the No.30 fuse in the under-dash fuse/relay box and the recirculation control motor.

5. Turn the ignition switch OFF.
6. Test the recirculation control motor.

Is the recirculation control motor OK?

YES - Go to step 7.

NO - Replace the recirculation control motor, or repair the recirculation control linkage or doors.

7. Disconnect audio-HVAC display panel connector B (16P).

Air Mix Control Motor Test|Page 6148 > < Air Mix Control Motor Test|Page 6146