honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Air Mix Control Motor Test|Page 6150 > < Air Mix Control Motor Test|Page 6148
Page 3
background image

11. Check for continuity between the following terminals of audio-HVAC display panel connector B (16P) and the recirculation control motor 7P

(4-door) or 5P (2-door) connector.

Is there continuity?

YES - Check for loose wires or poor connections at audio-HVAC display panel connector B (16P) and at the recirculation control motor 7P
(4-door) or 5P (2-door) connector. If the connections are good, substitute a known-good audio-HVAC display panel, and recheck. If the
symptom/indication goes away, replace the original audio-HVAC display panel.

NO - Repair any open in the wire(s) between the climate control unit and the recirculation control motor.

Heating and Air Conditioning

Recirculation Control Motor Circuit Troubleshooting

1. Check the No.30 (7.5 A) fuse in the under-dash fuse/relay box.

Is the fuse OK?

YES - Go to step 2.

NO - Replace the fuse, and recheck.

2. Disconnect the recirculation control motor 7P (4-door) or 5P (2-door) connector.
3. Turn the ignition switch ON (II).

Air Mix Control Motor Test|Page 6150 > < Air Mix Control Motor Test|Page 6148