Power Transistor HVAC: Testing and Inspection

Power Transistor Test

1. Disconnect the 4P connector from the power transistor.

2. Measure the resistance between the No.3 and No.4 (4-door) or No.1 and No.2 (2-door) terminals of the power transistor. It should be about 1.4 -

1.5 kOhms.

-

If the resistance is within the specifications, go to step 3.

-

If the resistance is not within the specifications, replace the power transistor.

Power Transistor HVAC|Locations|Page 6296 > < Power Transistor HVAC|Locations|Page 6294