Accord L4-2.4L (2005)
![background image](/honda/accord/l4-2.4l/Page-1111001.png)
Canister Vent Valve: Service and Repair
EVAP Canister Vent Shut Valve Replacement
Non-SULEV model
1. Remove the EVAP canister.
2. Pry the lock tabs outward (A) then remove the EVAP canister vent shut valve (B).
NOTE: Be careful not to damage the lock tabs.
3. Install the valve in the reverse order of removal with a new O-ring (C).
NOTE: Do not coat the O-ring with oil.
SULEV model
1. Remove the EVAP canister.
2. Remove the cap (A).
3. Remove the EVAP canister vent shut valve (B).
4. Install the valve in the reverse order of removal with a new O-ring (B).
NOTE: Do not coat the O-ring with engine oil.