23. Turn the ignition switch ON (II).
24. Measure the voltage between the No.3 terminal of the heater fan switch 7P connector and body ground.
Is there battery voltage?
YES - Go to step 25.
NO - Repair open in the wire between the blower motor and the heater fan switch.
25. Turn the ignition switch OFF.
26. Check for continuity between the No. 1 terminal of the heater fan switch 7P connector and body ground.
Is there continuity?
YES - Replace the heater fan switch.
NO - Check for an open in the wire between the heater fan switch and body ground. If the wire is OK, check for poor ground at G401 .
27. Disconnect the jumper wire.
28. Disconnect the blower motor 2P connector.
29. Measure the voltage between the No. 1 terminal of the blower motor 2P connector and body ground.
Is there battery voltage?