18.

Install the intake manifold with the original gasket. Torque the mounting nuts and bolts to 22 N.m (16 lb-ft) sequentially in two or three steps.
Route the PCV hose so it is not pinched under the intake manifold.

19.

Install the PCV valve in the cylinder head cover.

20.

Install the throttle body with a new gasket. Torque the mounting nuts and bolts to 22 N.m (16 lb-ft).

21.

Reinstall the brake booster vacuum hose, vacuum hose, ignition wire holder, and all of the covers.

22.

Connect the PGM Tester (loaded with SN200 or later software). Clear any DTCs.

23.

Use the PGM Tester to override two-trip error detection.

^

From the PGM tester menu, select 1. Honda Systems.

^

Then select 2. SCS.

24.

Test-drive the vehicle to make sure no new DTCs are set. *