3. Before connecting a new fuel tube/quick-connect fitting assembly (A), remove the old retainer from the mating line.
4. Align the quick-connect fittings with the line (A), and align the retainer (B) locking pawls with the connector (C) grooves. Then press the quick-
connect fittings onto the line until both retainer pawls lock with a clicking sound.
NOTE: If it is hard to connect, put a small amount of new engine oil on the line end.
5. Make sure the connection is secure and that the pawls are firmly locked into place; check visually and by pulling the connector.