Accord EX Sedan V6-2706cc 2.7L SOHC MFI (1997)
Fail Safe Relay: Testing and Inspection
^
Remove the fail-safe relays and motor relay. See: Brake Fluid Pump Relay/Locations
Relay Identification
^
Check for continuity between the terminals C and D. There should be continuity.
^
Check for continuity between the terminals A and B. There should be continuity when the battery is connected between the terminals C and D.
There should be no continuity when the battery is disconnected.