Accord LX Sedan L4-2156cc 2.2L SOHC MFI (1997)
Rocker Arm Assembly: Service and Repair
Inspection
Clearance Inspection
NOTE: Measure both the intake rocker shaft and exhaust rocker shaft.
1. Measure diameter of shaft at first rocker location.
2. Zero gauge to shaft diameter.
3. Measure inside diameter of rocker arm, and check for out-of-round condition.
^
Rocker Arm-to-Shaft Clearance:
-
Standard (New):
^
Intake: 0.017-0.050 mm (0.0007-0.0020 inch)
^
Exhaust: 0.018-0.054 mm (0.0007-0.0021 inch)
-
Service Limit: 0.08 mm (0.003 inch)