Mode Control Motor: Component Tests and General Diagnostics

Fresh Air/Recirculation Actuator

1. Connect battery power to the No. 1 terminal, and ground the No. 2 and No. 4 terminals; the recirculation control motor should run smoothly.

CAUTION:  Never connect the battery in the opposite direction.

2. Disconnect the No. 2 or No. 4 terminals from ground; the recirculation control motor should stop at FRESH or RECIRCULATE.

NOTE:  Don't cycle the recirculation control motor for a long time.

3. If the recirculation control motor does not run in step 1, remove it, and check the recirculation control linkage and doors for smooth movement. If

the recirculation control linkage and doors move smoothly, replace the recirculation control motor.

Control Motor Test

1. Connect battery power to the No. 1 terminal, and ground the No. 7 terminal.

CAUTION: Never connect the battery in the opposite direction.

Mode Control Motor - Test

2.  Using a jumper wire, connect the No. 7 terminal individually to the No. 2, 3, 4, 5 and 6 terminals in that order. Each time the connection is made,

the mode control motor should run smoothly and stop.

NOTE: If the mode control motor does not run when jumping the first terminal, jump that terminal again after jumping the other terminals.
The mode control motor is normal if it runs when jumping the first terminal again.

3.  If the mode control motor does not run in step 2, remove it, and check the mode control linkage and doors for smooth movement. If the mode

control linkage and doors move smoothly, replace the mode control motor.

Symptom Related Diagnostic Procedures|Page 7153 > < Symptom Related Diagnostic Procedures|Page 7151