Accord LX Sedan L4-2254cc 2.3L SOHC (VTEC) MFI (1998)
Backup Lamp Switch: Service and Repair
Back-Up Light Switch Test
1. Disconnect the back-up light switch (A) connectors.
2. Check for continuity between the terminals (B). There should be continuity when the shift lever into reverse.
3. If necessary, replace the switch.