Accord LX Sedan L4-2254cc 2.3L SOHC (VTEC) MFI (1998)
Intermittent Wiper Relay: Testing and Inspection
Five-terminal type A:
Check for continuity between the terminals.
-
There should be continuity between the No.1 and No.2 terminals when power and ground are connected to the No.3 and No.5 terminals.
-
There should be continuity between the No.2 and No.4 terminals when power is disconnected.
Windshield Wiper Intermittent Relay
Windshield Wiper Intermittent Relay