Condenser Fan: Testing and Inspection
Engine Cooling

Fan Motor Test 

1. Disconnect the 2P connectors from the radiator fan motor (A) and condenser fan motor (B).
2. Test the motor by connecting battery power to the No. 1 terminal, and ground to the No. 2 terminal.
3. If the motor fails to run or does not run smoothly, replace it.