honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Sensors and Switches - Computers and Control Systems > < Oxygen Sensor Relay|Locations
Page 1
background image

Oxygen Sensor Relay: Testing and Inspection

Normally-open type A:

Check for continuity between the terminals.

-

There should be continuity between the No.1 and No. 2 terminals when power and ground are connected to the No.3 and No. 4 terminals.

-

There should be no continuity between the No.1 and No.2 terminals when power is disconnected.

Heated oxygen sensor relay (California)

Sensors and Switches - Computers and Control Systems > < Oxygen Sensor Relay|Locations