Accord SE Sedan L4-2254cc 2.3L SOHC (VTEC) MFI (2002)
Evaporative Check Valve: Testing and Inspection
EVAP Two Way Valve Test
Special Tools Required
-
Vacuum pump/gauge, 0 - 30 in.Hg A973X-041-XXXXX
-
Vacuum/pressure gauge, 0 - 4 in.Hg 07JAZ-001000B
1. Remove the fuel fill cap.
2. Disconnect the vapor line from the EVAP two-way valve (A), and connect the line to a T-fitting (B) from the vacuum gauge and the vacuum pump
as shown.
3. Apply vacuum slowly and continuously while watching the gauge. The vacuum should stabilize momentarily at 0.8 - 2.1 kPa (6 - 16 mmHg, 0.2 -
0.6 in.Hg). If the vacuum stabilizes (valve opens) below 0.8 kPa (6 mmHg, 0.2 in.Hg) or above 2.1 kPa (16 mmHg, 0.6 in.Hg), install a new
valve and retest.
4. Move the vacuum pump hose from the vacuum fitting to the pressure fitting, and move the vacuum gauge hose from the vacuum side to the
pressure side (A) as shown.
5. Slowly pressurize the vapor line while watching the gauge. The pressure should stabilize momentarily above 1.0 kPa (8 mmHg, 0.3 in.Hg).
-
If the pressure momentarily stabilizes (valve opens) above 1.0 kPa (8 mmHg, 0.3 in.Hg), the valve is OK.
-
If the pressure stabilizes below 1.0 kPa (8 mmHg, 0.3 in.Hg), install a new valve and retest.