Accord SE Sedan L4-2254cc 2.3L SOHC (VTEC) MFI (2002)
NOTICE: Do not keep the pressure control valve closed more than 5 seconds or the pump could be damaged by over-heating.
10. Immediately open the pressure control valve fully. If the pump is in good condition, the gauge should read at least 7,200 - 7,800 kPa (73 - 80
kgf/cm2, 1,040 - 1,140 psi). A low reading means pump output is too low for full assist. Repair or replace the pump.