Ambient Temperature Sensor / Switch HVAC: Testing and Inspection

A/C Thermo Switch

Dip A/C thermo switch into a pan filled with ice water, and check for continuity between the terminals.

Cut off:  1.5--O.5°C (35-33°F) 
Cut in:  2.5-5°C (36-41°F)

If cut off or cut in temperature is too low or too high, replace the thermo switch.