Civic L4-1590cc 1.6L SOHC (VTEC) (1992)
Shift Interlock Control Module: Testing and Inspection
CONTROL UNIT INPUT TEST
Disconnect the 8-P connector from the control unit. Make the following input tests at the connector terminals. If all tests prove OK. yet the system
fails to work, substitute the control unt with a known good one. If the system is OK, replace the control unit.
NOTE: If the shift lock solenoid clicks when the ignition switch is ON and the brake pedal is pushed (the shift lever is in the P position), the shift
lock system is electronically normal.