Air Door Actuator / Motor: Testing and Inspection
Recirculation Control Motor Circuit Troubleshooting

Recirculation Control Motor Circuit Troubleshooting

1. Check the No.14 (10 A) fuse in the under-dash fuse/relay box.

Is the fuse OK?

YES - Go to step 2.

NO - Replace the fuse, and recheck.

2. Disconnect the recirculation control motor 7P connector.
3. Turn the ignition switch ON (II).

4. Measure the voltage between the No.1 terminal of the recirculation control motor 7P connector and body ground.

Is there battery voltage?

YES - Go to step 5.

NO - Repair open in the wire between the No.14 fuse in the under-dash fuse/relay box and the recirculation control motor.

5. Turn the ignition switch OFF.
6. Test the recirculation control motor.

Is the recirculation control motor OK?

YES - Go to step 7.

NO - Go to step 12.

7. Disconnect heater control panel connector A (14P).

8. Check for continuity between the No.5 and No.6 terminals of heater control panel connector A (14P) and body ground individually.

Is there continuity?

YES - Repair any short to body ground in the wire(s) between the heater control panel and the recirculation control motor.

NO - Go to step 9.