Keyless Entry Module: Testing and Inspection

1. Remove the driver's door panel.
2. Disconnect the 18P connector from the control unit.

3. Inspect the connector and socket terminals to be sure they are all making good contact.

-

If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.

-

If the terminals look OK, make the following input tests at the connector.
-

If any test indicates a problem, find and correct the cause, then recheck the system.

-

If all the input tests prove OK, the control unit must be faulty; replace it.

Disconnect the 18P connector from the power door lock control unit.

CAUTION:  To prevent damage to the actuator, apply battery voltage only momentarily.

Disconnect the 18P connector from the power door lock control unit. 