honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Shift Control Solenoid Valves <--> [Shift Solenoid, A/T] > < Key Interlock Solenoid Test
Page 1
background image

Shift Interlock Solenoid: Testing and Inspection
Shift Lock Solenoid Test

1. Remove the front console.
2. Disconnect the shift lock solenoid 2P connector.

3. Connect battery power to the No.1 terminal and ground to the No.2 terminal of the solenoid momentarily.

NOTE:  Do not connect power to the No.2 (-) terminal (reverse polarity) or you will damage the diode inside the solenoid.

4. Check that the shift lock releases when the release lever is pushed, and check that it locks when the release lever is released.
5. If the solenoid does not work, replace the solenoid.

Shift Control Solenoid Valves <--> [Shift Solenoid, A/T] > < Key Interlock Solenoid Test