honda Workshop Repair Guides

Honda Workshop Service and Repair Manuals

Blower Motor|Removal and Installation|Page 6993 > < Blower Motor|Removal and Installation
Page 2
background image

With Air Conditioning

4-b.

Remove the evaporator.

5. Disconnect the connectors from the blower motor, blower resistor ('96 - 98 models), power transistor ('99 - 00 models), blower motor high relay

('99 - 00 models) and recirculation control motor. 

Remove the wire harness clip from the recirculation control motor, and release the wire harness from the clamp on the blower unit. Remove the
two mounting bolts, the mounting nut and the blower unit.

6. Install in the reverse order of removal. Make sure that there is no air leakage.

Blower Motor|Removal and Installation|Page 6993 > < Blower Motor|Removal and Installation